Skip to main content
Emissions 10 min read Feb 11, 2026

What Your Air Permit Actually Costs

Title V fees are just the tip of the iceberg, and the thresholds that trigger major source status are lower than most facility managers realize

Air permits are the cost of doing business for any facility that emits regulated pollutants. But the true cost of an air permit extends far beyond the annual fee printed on your invoice. The difference between a minor source permit and a Title V major source permit can mean $50,000 to $200,000 in additional annual compliance costs, from monitoring and recordkeeping to consultant fees and reporting obligations. And the thresholds that determine which permit you need, sometimes as low as 10 tons per year for a single hazardous air pollutant, catch many facilities by surprise.

Understanding the permit cost structure is essential for making smart operational decisions. Adding a new boiler, switching fuel types, expanding a paint line, or increasing production hours can all push a facility across a regulatory threshold, triggering permit modifications or reclassification that cost far more than the equipment itself. This guide walks through the Title V threshold system, breaks down the real costs of major vs minor source status, and explains the strategies facilities use to stay below the thresholds that trigger the most expensive compliance obligations.

Title V Thresholds: The Numbers That Matter

Title V of the Clean Air Act requires any facility classified as a major source to obtain a Title V operating permit. The definition of major source depends on the pollutant and the area's attainment status. For criteria pollutants (NOx, SO2, CO, PM10, PM2.5, VOC, lead) in attainment areas, the major source threshold is 100 tons per year of potential to emit (PTE) for any single pollutant. In nonattainment areas, the thresholds drop significantly: serious ozone nonattainment areas use 50 tons/year for NOx or VOC, and extreme nonattainment areas use 10 tons/year.

For hazardous air pollutants (HAPs), the major source threshold is 10 tons per year of any single HAP or 25 tons per year of combined HAPs. These are lower thresholds than most facility managers expect. A facility that uses toluene-based coatings, methylene chloride in cleaning operations, or formaldehyde-containing resins can hit the 10-ton single HAP threshold faster than the 100-ton criteria pollutant threshold. HAP emissions are the most common unexpected trigger for major source classification.

Potential to emit is the critical concept. PTE is not your actual emissions, it is what you could emit if you ran every piece of equipment at maximum capacity, 24 hours a day, 365 days a year, without any add-on controls (unless those controls are federally enforceable). A paint booth that operates 8 hours a day but could theoretically operate 24 hours a day has a PTE based on 24-hour operation. A backup generator rated for continuous duty has a PTE based on 8,760 hours per year, even if it only runs 50 hours for testing. PTE is a worst-case number, and it is almost always much higher than actual emissions.

Facilities can take federally enforceable limits on their PTE to stay below the major source threshold. These are called synthetic minor permits, potential-to-emit limits, or voluntary curtailments depending on the state. By accepting enforceable limits on operating hours, production rates, material usage, or fuel consumption, a facility can reduce its PTE below the threshold and avoid Title V classification. The tradeoff is that these limits become legally binding conditions that must be monitored, recorded, and reported. Exceeding them is a permit violation.

Title V Major Source Thresholds:
Criteria pollutants (attainment): 100 tons/year PTE
Criteria pollutants (marginal nonattainment): 100 tons/year PTE
Criteria pollutants (moderate nonattainment): 100 tons/year PTE
Criteria pollutants (serious nonattainment): 50 tons/year PTE
Criteria pollutants (severe nonattainment): 25 tons/year PTE
Criteria pollutants (extreme nonattainment): 10 tons/year PTE
Single HAP: 10 tons/year PTE
Combined HAPs: 25 tons/year PTE
Emissions

Title V Permit Fee Calculator

Estimate annual Title V air permit fees based on actual pollutant emissions. Enter tons per year of each regulated pollutant to calculate state permit fees with major source threshold checks.

Launch Calculator →

The Real Cost of Major Source Status

Title V annual fees are the most visible cost. EPA's presumptive minimum fee is $25 per ton of actual emissions (adjusted for inflation), but most states charge significantly more. California charges up to $50-$100 per ton depending on the district. Texas charges fees based on a combination of emissions and facility size. Some states have minimum annual fees of $5,000-$15,000 regardless of emissions. A facility emitting 200 tons per year of combined pollutants can expect Title V fees of $10,000-$30,000 per year depending on the state.

Permit preparation and processing costs are the first hit. A Title V permit application requires a detailed emissions inventory, regulatory applicability analysis, compliance history review, and demonstration of compliance with all applicable requirements. The application itself can be 100-500 pages. Consultant fees for preparing a Title V application typically range from $20,000 to $75,000 for a moderately complex facility. State processing fees add another $5,000-$20,000. Permit renewal every five years repeats most of these costs.

Ongoing compliance obligations drive the largest share of major source costs. Title V permits require continuous compliance monitoring, periodic source testing (typically every 1-5 years at $5,000-$20,000 per test), semi-annual compliance certifications, annual compliance reports, prompt deviation reporting, and detailed recordkeeping. Many facilities need a part-time or full-time environmental compliance staff member just to manage Title V obligations. Salary and benefits for an environmental compliance coordinator run $50,000-$80,000 per year, and many larger facilities have entire environmental departments.

MACT (Maximum Achievable Control Technology) standards apply only to major sources of HAPs. If your facility is classified as a major source due to HAP emissions, you become subject to the MACT standards for your source category (40 CFR Part 63). MACT compliance can require installation of add-on controls (thermal oxidizers, scrubbers, carbon adsorbers), continuous emissions monitoring, and detailed work practice standards. The capital cost of MACT compliance ranges from $50,000 to over $1,000,000 depending on the source category and the controls required. This is the cost that drives many facilities to take synthetic minor limits rather than accept major source classification.

Warning: True annual cost of major source status:
Title V fees: $10,000–$30,000
Compliance staff time: $20,000–$80,000
Consultant support: $5,000–$15,000
Source testing: $5,000–$20,000 (annualized)
Monitoring/recordkeeping systems: $5,000–$15,000
MACT compliance (if applicable): $10,000–$100,000+

Total: $55,000–$260,000+/year beyond minor source costs.

Strategies to Stay Below Major Source Thresholds

The most common strategy for avoiding major source status is accepting federally enforceable limits on operations. These synthetic minor or potential-to-emit (PTE) limits cap your legal emissions below the applicable threshold by restricting hours of operation, material usage, production rates, or fuel consumption. For example, a facility whose boiler could emit 120 tons/year of NOx at full capacity can accept a fuel usage limit that caps NOx PTE at 95 tons/year, staying below the 100-ton major source threshold.

Material substitution is often more effective than operational limits because it permanently reduces emissions without constraining production. Switching from solvent-based coatings (4-6 lbs VOC/gallon) to waterborne coatings (0.5-2 lbs VOC/gallon) can cut VOC emissions by 60-80%. Replacing a HAP-containing cleaning solvent with a non-HAP alternative eliminates HAP emissions from that source entirely. These changes reduce PTE without limiting operating hours or production volume.

Production netting allows facilities to offset emissions increases from new equipment against decreases from shutting down or modifying existing equipment. If you are adding a new paint line that will emit 15 tons/year of VOC but simultaneously decommissioning an old line that emitted 20 tons/year, the net change is a 5-ton decrease. This approach requires careful documentation and may need to be formalized in a permit modification, but it allows facilities to modernize equipment without crossing thresholds.

Pollution control equipment with federally enforceable requirements can also reduce PTE. A paint booth with a thermal oxidizer destroying 98% of VOC emissions has a PTE based on the post-control emission rate, not the uncontrolled rate. However, the control requirement must be made federally enforceable through a permit condition, and the facility must maintain, operate, and monitor the control equipment as specified. If the oxidizer goes down, the facility must either stop operations or accept the uncontrolled PTE, which may push it above the threshold. This approach trades operating flexibility for lower PTE.

Tip: Before adding new equipment, run the numbers:
1. Calculate the new source's PTE (worst case, maximum hours)
2. Add it to your current facility PTE for each pollutant
3. Compare to the applicable major source thresholds
4. If any pollutant exceeds the threshold, evaluate options:
  • Accept operational limits on the new or existing sources
  • Substitute lower-emission materials
  • Install controls with enforceable conditions
  • Offset with shutdowns or modifications elsewhere
Emissions

VOC Emissions from Coating Calculator

Calculate VOC emissions from paint, primer, and coating operations. Accounts for transfer efficiency, capture systems, and control devices. Supports conventional spray, HVLP, electrostatic, and dip applications.

Launch Calculator →

Recordkeeping: The Compliance Cost Nobody Budgets

Air permit recordkeeping requirements are where the real operational burden lives. Every synthetic minor limit, every emission factor assumption, and every compliance demonstration method in your permit generates a recordkeeping obligation. A facility with limits on fuel usage, coating usage, operating hours, and production volume needs to track all four parameters continuously, verify them monthly, and report them annually. The records must be maintained for at least five years and made available to inspectors upon request.

Fuel records are the foundation for combustion emission calculations. Track fuel purchases (delivery receipts, meter readings, or utility bills), consumption by unit (submeters or allocation methods), and heating value (use supplier certifications or default EPA values). For facilities with synthetic minor limits on fuel consumption, monthly tracking is essential to ensure the annual limit is not exceeded. If you reach 85% of your annual limit by October, you need to reduce consumption for the remaining months or risk a permit violation.

Material usage records are critical for VOC and HAP emission calculations. Track purchases and usage of every coating, solvent, adhesive, sealant, and cleaning chemical that contains VOC or HAP compounds. Maintain SDS or technical data sheets for every material, including the VOC content (lbs/gallon) and the identity and concentration of any HAP components. Material balance calculations based on these records are your primary emission estimation method and the basis for demonstrating compliance with permit limits.

Many facilities fail inspections not because they exceed their emission limits but because their records are incomplete, disorganized, or cannot demonstrate compliance. A state inspector who asks to see your monthly VOC usage records and receives a box of purchase orders with no summary calculations will not be satisfied. Maintain a spreadsheet or database that calculates rolling 12-month emissions for each pollutant at each source, compares them to permit limits, and flags any readings above 80% of the limit. This turns recordkeeping from a compliance burden into an early warning system.

Tip: Records every facility should maintain:
1. Monthly fuel consumption by unit (therms, gallons, MCF)
2. Monthly coating/solvent usage by product (gallons)
3. SDS for every VOC/HAP-containing material on site
4. Equipment operating hours (for hour-limited sources)
5. Rolling 12-month emission totals for each pollutant
6. Combustion analyzer readings (annual minimum)
7. Maintenance logs for any required control equipment
Emissions

Fuel Combustion Emissions Calculator

Calculate CO2, NOx, SOx, and PM emissions from fuel combustion using EPA AP-42 emission factors. Supports natural gas, propane, diesel, fuel oil, and coal with annual emissions totals and cost-per-ton estimates.

Launch Calculator →

State-by-State Fee Structures

Title V fee structures vary widely by state because EPA sets a minimum (the presumptive minimum fee) but allows states to design their own fee programs as long as they collect enough revenue to fund the permitting program. Some states charge a flat per-ton fee on actual emissions. Others use tiered systems where the per-ton rate decreases for higher emission levels. Some charge a combination of base fees, per-ton fees, and application processing fees.

At the low end, states like Wyoming and Montana charge relatively modest Title V fees, reflecting smaller regulatory programs and lower cost of living. At the high end, California air quality management districts charge some of the highest fees in the nation, with the South Coast AQMD (Los Angeles area) charging fees that can exceed $100,000 per year for large emitters. States in the Northeast, including New York, New Jersey, and Massachusetts, also tend to have higher-than-average fee structures.

Fee structures also differ in what they count. Some states charge fees on all criteria pollutants plus HAPs. Others charge only on the pollutants that trigger major source status. Some states cap total fees at a maximum amount regardless of emissions, while others have no cap. A facility with 500 tons/year of combined emissions might pay $15,000 in one state and $75,000 in another for essentially the same regulatory coverage.

For facilities near state borders or with multiple locations, the fee structure differences can influence siting decisions. A new manufacturing facility that will be a Title V source in any location might save $50,000+ per year in permit fees by choosing a state with a lower fee structure, all else being equal. This is a legitimate business consideration, though it should be weighed against differences in enforcement philosophy, permitting timelines, and the overall regulatory climate. A state with low fees but strict enforcement and slow permitting may cost more in the long run than a state with higher fees but predictable, efficient permitting.

Fee comparison example (200 tons/year facility):
Low-fee state: $5,000–$10,000/year
Average state: $10,000–$20,000/year
High-fee state: $25,000–$50,000/year
California (SCAQMD): $50,000–$100,000+/year

Check your state environmental agency's fee schedule annually, as rates change frequently.

Frequently Asked Questions

Actual emissions are what you actually released based on real operating data. Potential to emit (PTE) is what you could release if you ran every source at maximum capacity, 24/7/365, without controls (unless controls are federally enforceable). PTE determines your permit classification (major vs minor). Actual emissions determine your annual fees and compliance with specific emission limits.
Yes. A synthetic minor permit places federally enforceable limits on your operations (hours, fuel use, material usage, production rates) that reduce your PTE below the major source threshold. You avoid Title V but must comply with the limits. Exceeding a synthetic minor limit is a permit violation, so the limits must be realistic and achievable under all normal operating conditions.
Initial Title V permit issuance typically takes 18 to 36 months from application submission. Some states have backlogs that extend timelines to 3-5 years. During the application period, the facility operates under an application shield that provides interim authorization, but this does not exempt the facility from compliance with applicable requirements.
Operating as a major source without a Title V permit is a violation of the Clean Air Act. Penalties can include fines up to $64,618 per day per violation (2024 adjusted amount), injunctive relief requiring installation of controls, and potential criminal prosecution for knowing violations. If you discover that your facility exceeds a threshold, consult with an environmental attorney immediately.
Under the EPA Tailoring Rule (currently in legal flux), facilities that are major sources for a conventional pollutant and also emit 100,000 tons/year of CO2e must address GHGs in their Title V permit. A facility that is minor for all conventional pollutants is not triggered into Title V by GHG emissions alone. This area of law is evolving and may change.
Disclaimer: This guide provides general information about air permitting under the Clean Air Act. Permit requirements, fee structures, and thresholds vary by state, county, and attainment area. This is not legal advice. Consult with a qualified environmental attorney or consultant and your state or local air quality agency for facility-specific permitting guidance. Permit applicability determinations should be made by or with the oversight of qualified environmental professionals.

Calculators Referenced in This Guide

Emissions Live

Fuel Combustion Emissions Calculator

Calculate CO2, NOx, SOx, and PM emissions from fuel combustion using EPA AP-42 emission factors. Supports natural gas, propane, diesel, fuel oil, and coal with annual emissions totals and cost-per-ton estimates.

Emissions Live

Title V Permit Fee Calculator

Estimate annual Title V air permit fees based on actual pollutant emissions. Enter tons per year of each regulated pollutant to calculate state permit fees with major source threshold checks.

Emissions Live

VOC Emissions from Coating Calculator

Calculate VOC emissions from paint, primer, and coating operations. Accounts for transfer efficiency, capture systems, and control devices. Supports conventional spray, HVLP, electrostatic, and dip applications.

Related Guides

Emissions 10 min

Where Your Facility's Emissions Actually Come From

Most facilities undercount their emission sources. Combustion, refrigerants, coatings, and backup generators all add up - and the permit math starts with knowing what you're actually releasing.

Emissions 8 min

Your Paint Booth and the EPA