Tools & Calculators

A catalog of trade calculators for field checks, shop math, and planning estimates. Search by work, material, standard, or category.

Electrical

35 live tools

Branch-circuit and feeder screening against NEC table data: wire sizing, panel load studies, generator sizing, and code translators.

Showing Electrical tools. 35 shown.

Tools in Electrical

Electrical

35 tools
Electrical
Pro Live

ABB ACS Drive Type-Code Decoder

Decode an ABB ACS drive type designation (ACS180, ACS355, ACS380, ACS480, ACS580, ACS880) into output current I2N, max current Imax, Normal-Duty and Heavy-Duty motor power (kW and HP), frame size, voltage class, enclosure, and +options. Reads the rating from ABB's published tables and flags when a current code does not exist at the entered voltage.

Electrical
Pro Live

Available Fault Current Estimator

Calculate available fault current at any point in an electrical system. Point-to-point method for breaker AIC rating using transformer kVA, impedance, and wire run length.

Electrical
Pro Live

Battery Energy Storage System (BESS) Sizing Calculator

Size commercial battery storage for peak shaving, TOU arbitrage, solar self-consumption, and backup with degradation modeling, IRA ITC analysis, and LCOS.

Electrical
Pro Live

Cable Tray Fill Calculator (NEC 392)

Calculate cable tray fill per NEC Article 392 for ladder, ventilated trough, solid bottom, and channel trays. Multi-conductor and single-conductor rules.

Electrical
Pro Live

Can I Run This On That?

Check if your circuit breaker and wiring can handle a specific appliance. Enter breaker size, wire gauge, and load wattage for a pass/fail verdict based on NEC standards.

Electrical
Pro Live

Conduit Bending Calculator

Conduit bending calculator for EMT and rigid conduit. Benfield method for offsets, saddles, stub-ups, and back-to-back 90s. Shrink, multipliers, and marks.

Electrical
Pro Live

Danfoss VLT Drive Decoder

Decode a Danfoss VLT FC type code (FC 301/302 AutomationDrive, FC 102 HVAC, FC 202 AQUA, FC 51 Micro Drive) into motor kW/HP, captured output currents, voltage class, and frame size. FC 102 current coverage is incomplete and flagged in the result. The power code is a kW key (PK75 = 0.75 kW, P11K = 11 kW), not a current, and the decoder rejects power/voltage combinations that are not cataloged instead of fabricating a number.

Electrical
Pro Live

Data Center Power & Cooling Load Calculator

Calculate electrical power requirements and cooling loads for data center spaces with PUE estimation, redundancy planning, and carbon footprint analysis.

Electrical
Pro Live

EV Charger Load & Panel Fit Check

Determine if your electrical panel can support an EV charger installation. Calculates NEC demand load, continuous load 125% sizing, wire sizing with voltage drop, and shows panel pass/marginal/fail with upgrade options including NEC 625.42 energy management.

Electrical
Pro Live

Electrical Service & Transformer Sizing Calculator

Size transformers using NEC Article 220 demand factors. Enter your load inventory to calculate demand kVA and select the standard transformer size for single-phase or three-phase service.

Electrical
Pro Live

Generator Sizing Calculator

What size generator do you need? Add your appliances and loads to calculate total running watts and starting surge. Get a recommended generator size with built-in headroom.

Electrical
Pro Live

Grounding Electrode System Calculator

Calculate ground resistance for single rods, parallel rods, ground rings, and ground grids using Dwight's formulas per IEEE 142. Includes soil resistivity reference and NEC 250 pass/fail check.

Electrical
Pro Live

Hazardous Area Code Translator

Decode a NEC Class/Division marking, an IEC/IECEx Ex string, or an ATEX marking, and translate between the systems. Surfaces the reversed gas-group lettering (NEC Group A is IEC IIC) and the lossy or ambiguous hops most cross-references hide.

Electrical
Pro Live

Hazardous Location Classification Guide

Interactive decision-tree for NEC Article 500 (Class/Division) and Article 505 (Class/Zone) hazardous location classification. Identifies Group, T-code, and equipment requirements from the material present.

Electrical
Pro Live

Junction Box Fill Calculator

NEC 314.16 junction box fill calculator. Count conductors, devices, and clamps to check cubic inch capacity. Avoid failed rough-in inspections.

Electrical
Pro Live

Lighting Design / Foot-Candle Calculator

Calculate fixture count using the IES lumen method with Room Cavity Ratio, Coefficient of Utilization, and light loss factors. Includes IES illuminance targets for 15 space types, LED retrofit comparison, and IECC energy code compliance checks.

Electrical
Pro Live

Motor FLA Lookup (NEC 430)

NEC Table 430.248 and 430.250 motor full-load current lookup with overload sizing, breaker/fuse sizing per 430.52, and wire sizing per 310.16.

Electrical
Pro Live

Motor Starting Current / Code Letter Calculator

Convert NEC code letters (A through V) to locked-rotor starting amps. Starting-to-running ratio and starter recommendation for any motor.

Electrical
Pro Live

Motor Starting Voltage Drop Calculator

Screen motor-start terminal voltage drop with local code-letter, transformer, and cable rows plus IEEE 3002.7, NEC/NEMA, utility, AHJ, and safe-work review boundaries.

Electrical
Pro Live

NEC Conduit Fill Calculator

Calculate NEC Chapter 9 conduit fill for mixed conductor types. Check percent fill against code limits, get violation flags, and find the next size up recommendation.

Electrical
Pro Live

NEMA Plug & Receptacle Reference

Interactive source-aware screen for common local NEMA plug and receptacle rows. Filter by voltage, amperage, grounding, and locking style while keeping WD 6, UL/listing, NEC, and AHJ gaps visible.

Electrical
Pro Live

Ohm's Law / Power Wheel Calculator

All 12 Ohm's Law and Watt's Law relationships for DC, single-phase AC, and three-phase AC. Power triangle visualization with kW, kVA, kVAR, and power factor.

Electrical
Pro Live

Panel Load Study

Do you actually need a panel upgrade? Walk your breaker panel with NEC Article 220 demand factors. See connected load vs. calculated demand and test whether an EV charger, heat pump, or hot tub fits.

Electrical
Pro Live

Power Factor Correction Calculator

Calculate capacitor bank sizing for power factor correction with cost savings analysis.

Electrical
Pro Live

PowerFlex Drive Decoder

Decode an Allen-Bradley / Rockwell PowerFlex catalog number into output current, Normal-Duty motor HP/kW, voltage class, frame, enclosure, and options. Handles both the dash-delimited 520-series (523 = 25A, 525 = 25B) and the fixed 18-character 750-series (753 = 20F, 755 = 20G, 755 with Options = 21G), and flags when a code, voltage, or frame combination is not a real drive.

Electrical
Pro Live

Residential Electrical Load Calculator (NEC 220)

Calculate residential electrical service size using NEC 220.82 (new construction) and 220.83 (existing dwelling additions). Step-by-step demand breakdown with HVAC exclusive rule, EV charger loads, conductor sizing for copper and aluminum.

Electrical
Pro Live

Square D Breaker Decoder

Decode a Square D QO / QOB / Homeline circuit-breaker catalog number (QO120, QO230, HOM250) into poles, amperage, voltage, and interrupting rating (AIC). The AIC is read from the Schneider interrupting-rating matrix on the full code: standard QO/QOB/HOM = 10 kA, QO-VH = 22 kA, QOH = 42 kA, QH = 65 kA, and a lone H on a 2-pole QO is a 240 Vac common-trip device that is still 10 kA. A combination not in the matrix is flagged needs-source, never guessed; PowerPacT/I-Line are out of scope. Always verify against the breaker label.

Electrical
Pro Live

Torque to Horsepower Converter

Convert between torque and horsepower (or kW). HP = (T x RPM) / 5252. Includes efficiency chain, gearbox ratios, and quick reference table.

Electrical
Pro Live

Transformer Fault Current Calculator

Available fault current at transformer secondary and downstream points. Point-to-point method with AIC rating recommendation.

Electrical
Pro Live

Transformer Loss Evaluation (TOC) Calculator

Calculate total owning cost of transformers using the A and B factor method per IEEE C57.120. Compare up to 3 units with DOE 2016 efficiency checks.

Electrical
Pro Live

Transformer Protection Calculator

Size transformer overcurrent protection per NEC 450.3. Primary and secondary fuse or breaker sizing for single-phase and three-phase transformers up to 1000V.

Electrical
Pro Live

VFD Cross-Reference

Cross-reference a variable frequency drive across ABB ACS, Allen-Bradley PowerFlex, Yaskawa, and Danfoss VLT. Enter one drive by model code or by parameters (phase, voltage, motor kW/HP, duty, optional current) and get the closest equivalents in the other brands, matched on the electrical envelope with every difference shown. A sourcing starting point, not a certified drop-in: it does not verify dimensions, wiring, controls, safety, firmware, or approvals.

Electrical
Pro Live

Wire & Cable Type Decoder

Decode a wire or cable marking (THWN-2, XHHW-2, SOOW, MC, NM-B, TC-ER, USE-2) into temperature ratings, ampacity basis, permitted locations, construction, and the governing UL standard. Built around the "-2" wet-rating trap and the NEC 110.14(C) termination ampacity gap.

Electrical
Pro Live

Wire Sizing Calculator

Find the right AWG wire gauge for any electrical run. Enter amps, distance, and voltage to get NEC-compliant sizing with derating, voltage drop, and copper vs aluminum cost comparison.

Electrical
Pro Live

Yaskawa Drive Decoder

Decode a Yaskawa AC drive code into Heavy-Duty and Normal-Duty output current, motor HP/kW, voltage class, EMC filter, and enclosure. Full 7-position decode for GA500 (CIPR-GA50U...) and GA800 (CIPR-GA80U...); legacy A1000 (CIMR-A...) and V1000 (CIMR-V...) are recognized and their ratings returned. Ratings are keyed on family plus model because the same model token (e.g. 2030) carries a different kW on the GA500 than on the GA800.

Find the Right Calculator Faster

Start with a trade, then search the actual job term: ampacity, snow load, grease trap, bearing life, voltage drop, or pipe schedule. The URL keeps the filter so the same list can be reopened.